Toshiba CB-426-T3-QQ Printer User Manual


 
Appendix 2 DIP Switches
81
1
2
3
4
5
6
7
8
12
OFF OFF
ON OFF
OFF ON
ON ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
78
OFF OFF
ON OFF
OFF ON
ON ON
2400 BPS
4800 BPS
9600 BPS
19200 BPS
1 bit
2 bits
7 bits
8 bits
Without
With
EVEN
ODD
XON/XOFF
(No XON is output at the
power on time)
(No XOFF is output at the
power off time.)
READY/BUSY (DTA)
(No XON is output at the
power on time)
(No XOFF is output at the
power of time)
XON/XOFF+READY/
BUSY
(XON is output at the
power on time)
(XOFF is output at the
power of time)
XON/XOFF
(XON is output at the
power on time.)
(XOFF is output at the
power off time.)
Baud rate
Stop bit length
Data length
Parity check
Parity check
(effective when DIP
SW #5 set to ON.)
Data protocol
No.
ON/OFF FunctionA2.2 DIP Switch B
Note:
The shaded areas are the factory
default settings.
“OFF” means “OPEN”.