- 66 -
In the case of MSI, Interleaved 2 of 5, CODE39, NW7, and Industrial 2 of 5
Format [ESC] XBaa; bbbb, cccc, d, e, ff, gg, hh, ii, jj, k, llll (, mnnnnnnnnnn, p, qq) (, r)
(=sss------sss) [LF] [NUL]
[ESC] XBaa; bbbb, cccc, d, e, ff, gg, hh, ii, jj, k, llll (, mnnnnnnnnnn, p, qq) (, r)
(; tt
1
, tt
2
, tt
3
, ------, tt
20
) [LF] [NUL]
Term aa: Bar code number
00 to 31
bbbb: Print origin of X-coordinate of the bar code
Fixed as 4 digits (in 0.1 mm units)
cccc: Print origin of Y-coordinate of the bar code
4 or 5 digits (in 0.1 mm units)
d: Type of bar code
1: MSI
2: Interleaved 2 of 5 (ITF)
3: CODE39 (standard)
4: NW7
B: CODE39 (full ASCII)
O: Industrial 2 of 5
e: Type of check digit
1: Without attaching check digit
2: Check digit check
CODE39 Modulus 43
MSI IBM modulus 10
ITF Modulus 10
Industrial 2 of 5 Modulus check character
3: Check digit auto attachment (1)
CODE39 Modulus 43
MSI IBM modulus 10
ITF Modulus 10
Industrial 2 of 5 Modulus check character
4: Check digit auto attachment (2)
MSI IBM modulus 10 + IBM modulus 10
ITF DBP Modulus 10
5: Check digit auto attachment (3)
MSI IBM modulus 11 + IBM modulus 10
ff: Narrow bar width
01 to 99 (in dots)
gg: Narrow space width
01 to 99 (in dots)
* In the case of industrial 2 of 5, an element-to-element space is designated.
hh: Wide bar width
01 to 99 (in dots)