Toshiba GC10-QM Barcode Reader User Manual


 
- 4 -
XON/XOFF (DC1/DC3) Protocol + READY/BUSY (DTR) Protocol
When initialized after power on, this printer becomes ready to receive data and turns the
DTR signal to “High” level (READY). The printer also sends an XON code (11H).
When the blank positions in the receive buffer are 1K bytes or less, the printer turns the
DTR signal to “Low” level (BUSY) and sends an XOFF code (13H).
When the blank positions in the receive buffer are 2K bytes or more, the printer turns the
DTR signal to “High” level (READY) and sends an XON code (11H).
When there are no blank positions in the receive buffer, the printer discards data received
exceeding the receive buffer capacity, without storing it in the buffer. (After detecting the
XOFF code or BUSY signal, the host computer must stop transmission before the printer
receive buffer becomes full.)
The printer sends an XOFF code (13H) when the power is off.
The RTS signal is always “High”.
RTS Protocol
When initialized after the power is turned on, this printer turns the RTS signal to “High”
(READY).
The printer turns the RTS signal to “Low” (BUSY) when the blank positions in the receive
buffer are 1K bytes or less.
The printer turns the RTS signal to “High” (READY) when the blank positions in the receive
buffer are 2K bytes or more.
When there are no blank positions in the receive buffer, the printer discards data received
exceeding the receive buffer capacity, without storing it in the buffer. (After detecting the
BUSY signal, the host computer must stop transmission before the printer receive buffer
becomes full.)
The DTR signal is always “High” (READY).