User's Manual
D-4
APPENDIX D
S7 Connection completion time-out
This register sets the time, in seconds, that the modem must wait
before hanging up because carrier is not detected. The timer is started
when the modem finishes dialing (originate), or goes off-hook
(answer). In originate mode, the timer is reset upon detection of an
answer tone if allowed by county restriction. The timer also specifies
the wait for silence time for the @ dial modifier in seconds. S7 is not
associated with the W dial modifier.
Range: 1-255
Default: 50
Units: seconds
S8 Comma pause time
This register sets the time, in seconds, that the modem must pause
when it encounters a comma (,) in the dial command string. In some
countries/regions, S8 will set both wait before dialing and comma
pause time.
Range: 0-255
Default: 2
Units: seconds
S11 DTMF dialing speed
This register determines the dialing speed which is prefixed for each
country/region.
Range: 50-255
Default: 95
Units: .001 seconds
S12 Escape guard time
This register sets the value (in 20 millisecond increments) for the
required pause after the escape sequence.
Range: 0-255
Default: 50
Units: .02 seconds