Uniden BCD996T Scanner User Manual


 
109
Search and Close Call Options
AM — the scanner uses AM (amplitude modulation) for the frequency band.
FM — the scanner uses FM (frequency modulation) for the frequency band.
NFM — the scanner uses narrowband FM for the frequency band.
WFM — the scanner uses wideband FM for the frequency band.
WFM (Broadcast) — the scanner uses FM Broadcast for the frequency band.
Setting Attenuation
Turn on this setting if you are near other strong signal sources. Attenuation
sometimes helps to reduce interference and desensitization that strong signals
create.
[MENU]
J4Srch/CloCall Opt JF
4 Set Attenuator JF
This setting controls the attenuator for Quick Search and Close Call operation.
Select your setting, then press
F.
On — Reception is attenuated by about 20 dB.
Off — Attenuation is off.
Setting Data Skip
[MENU] J4Srch/CloCall Opt JF
4 Set Data Skip JF
This setting controls how the scanner behaves when it stops on a channel that has
a data signal.
On — the scanner stops briefly on the channel, but then immediately resumes
scanning automatically.
Off — the scanner remains on the channel until the transmission stops. The
default setting is Off.
Note: If you are trying to test the Close Call feature with a nearby transmitter (such
as a CB) and you do not talk into the transmitter, the scanner detects this
unmodulated carrier as data and skips the frequency when Data Skip is on. Turn
the feature off or talk into the transmitter to modulate the carrier.
This setting is ignored for AM/WFM/FMB channels.