Uniden BCD996T Scanner User Manual


 
81
Programming Your Scanner
4 Select a site JF
4 Edit Band Plan JF
You can enter up to 3 band plans. Select the plan to enter or edit, then follow the
prompts to enter the Base Frequency, Channel Step, and Channel Offset for the
site.
The BCD996T includes two operation modes for P25 systems: explicit mode and
implicit mode channel assignment. Explicit mode systems include all information
needed to determine voice frequencies on the control channel. You must supply
the system’s band plan for implicit systems for the scanner to correctly determine
voice frequencies.
To set the band plan for a P25 system:
[MENU]
J Program System JF
4 Edit Site JF
4 Edit Band Plan JF
Then, follow these steps:
1.
4 the Band Plan table entry you want to edit and JF.
2. Enter the base frequency for the table entry and
JF.
3. Enter the spacing for the table entry (in kHz) and
JF.
Repeat 1-3 for additional table entries.
Notes:
For Explicit mode systems, leave all entries blank.
There is no way to determine the correct entries using the scanner (other than
trial and error). You must get this information from another source. Uniden
America Corporation does not have this information.
[MENU]
J Program System JF
4 Select a trunked system JF
4 Edit Site (current) JF
4 Select a non-P25 site JF
4 Set C-Ch Only JF
Setting P25 Band Plans (P25 Only)
Setting Control-Channel Only Mode M (except for P25)