Register Default Function
S0 See DIP Sets the number of rings on which to
Switch 5 answer when in Auto Answer mode. S0=0
disables Auto Answer, the same as DIP
switch 5 ON (factory setting). S0=1
enables Auto Answer and the modem
answers on the first ring.
NOTE: If DIP switch 5 is OFF and S0=0,
Auto Answer remains disabled.
S1 0 Counts and stores the number of rings
from an incoming call.
S2 43 Stores the ASCII decimal code for the
escape code character. Default character is
“+”. A value of 128-255 disables the
escape code.
S3 13 Stores the ASCII decimal code for the
Carriage Return character. Valid range is
0127.
S4 10 Stores the ASCII decimal code for the Line
Feed character. Valid range is 0127.
S5 8 Stores the ASCII decimal code for the
Backspace character. A value of 128-255
disables the Backspace key's delete
function.
S6 2 Sets the number of seconds the modem
waits before dialing. If set to X2, X4, X6,
or X7, the modem dials as soon as it
detects a dial tone (fast dials). If there is
no dial tone, the modem observes the
normal S6 timeout.
S7 60 Sets the number of seconds the modem
waits for a carrier. May be set for much
longer duration if, for example, the
modem is originating an international
connection.