Xantrex Technology XPR 20-300 Power Supply User Manual


 
Remote Operation
Select Remote Control Function
Release 1.1 63
Table 4.3 Power Supply Settings for Different Programming Sources
Note: The front panel RMT/LCL switch may be pressed at any time, to force both the voltage and
current setpoints to be remotely controlled via the J1 inputs.
Power Supply Output Current Limit: Programming Source
0-5 Vdc 0-10 Vdc 0-5 k Resistor 0-10 k Resistor None (Front
Panel Control:
Local Mode)
S1-1= OFF S1-1= OFF S1-1= OFF S1-1= OFF S1-1= OFF
S1-2= OFF S1-2= OFF S1-2=ON S1-2=ON S1-2= OFF
S1-3= OFF S1-3= OFF S1-3= OFF S1-3= OFF S1-3= OFF
S1-4= OFF S1-4=ON S1-4= OFF S1-4=ON S1-4= OFF
S1-5=ON S1-5=ON S1-5=ON S1-5=ON S1-5=ON
S1-6=ON S1-6=ON S1-6=ON S1-6=ON S1-6= OFF
S1-1= OFF S1-1= OFF S1-1= OFF S1-1= OFF S1-1= OFF
S1-2= OFF S1-2= OFF S1-2=ON S1-2=ON S1-2= OFF
S1-3=ON S1-3=ON S1-3=ON S1-3=ON S1-3=ON
S1-4= OFF S1-4=ON S1-4= OFF S1-4=ON S1-4=ON
S1-5=ON S1-5=ON S1-5=ON S1-5=ON S1-5=ON
S1-6=ON S1-6=ON S1-6=ON S1-6=ON S1-6= OFF
S1-1=ON S1-1=ON S1-1=ON S1-1=ON S1-1=ON
S1-2= OFF S1-2= OFF S1-2=ON S1-2=ON S1-2= OFF
S1-3= OFF S1-3= OFF S1-3= OFF S1-3= OFF S1-3= OFF
S1-4= OFF S1-4=ON S1-4= OFF S1-4=ON S1-4= OFF
S1-5=ON S1-5=ON S1-5=ON S1-5=ON S1-5=ON
S1-6=ON S1-6=ON S1-6=ON S1-6=ON S1-6= OFF
S1-1=ON S1-1=ON S1-1=ON S1-1=ON S1-1=ON
S1-2= OFF S1-2= OFF S1-2=ON S1-2=ON S1-2= OFF
S1-3=ON S1-3=ON S1-3=ON S1-3=ON S1-3=ON
S1-4= OFF S1-4=ON S1-4= OFF S1-4=ON S1-4=ON
S1-5=ON S1-5=ON S1-5=ON S1-5=ON S1-5=ON
S1-6=ON S1-6=ON S1-6=ON S1-6=ON S1-6= OFF
S1-1= OFF S1-1= OFF S1-1= OFF S1-1= OFF
S1-1= OFF
S1-2= OFF S1-2= OFF S1-2=ON S1-2=ON
S1-2= OFF
S1-3= OFF S1-3=ON S1-3= OFF S1-3=ON
S1-3=ON
S1-4= OFF S1-4=ON S1-4= OFF S1-4=ON
S1-4=ON
S1-5= OFF S1-5= OFF S1-5= OFF S1-5= OFF
S1-5= OFF
S1-6=ON S1-6=ON S1-6=ON S1-6=ON
S1-6= OFF
!
CAUTION
To prevent possible damage, the power supply settings for different sources must be strictly used as
shown in Table 4.3, “Power Supply Settings for Different Programming Sources,” on page 63.
Power Supply Output Voltage: Programming Source
0-5 Vdc0-10 Vdc0-5 k Resistor0-10 k ResistorNone (Front Panel
Control: Local
Mode)
Default settings