Xantrex Technology XPR 20-300 Power Supply User Manual


 
Specifications and Characteristics
Electrical Specifications—Summary
Release 1.1 69
Table A.4Drift Specifications for 6000 Watt units (80V to 600V Models)
Models 80–75 100–60 150–40 300–20 600–10
Drift (30 minutes):
1
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
32 mV
450 mA
40 mV
360 mA
60 mV
240 mA
120 mV
120 mA
240 mV
60 mA
Drift (8 hours):
2
Voltage (0.02% of Vmax)
Current (0.04% of Imax)
2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
16 mV
30 mA
20 mV
24 mA
30 mV
16 mA
60 mV
8mA
120 mV
4mA
Temperature Coefficient:
3
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
3. Change in output per °C change in ambient temperature, with constant line and load.
32 mV
45 mA
40 mV
36 mA
60 mV
24 mA
120 mV
12 mA
240 mV
6mA