Xantrex Technology XPR 20-300 Power Supply User Manual


 
Specifications and Characteristics
Electrical Specifications—Summary
Release 1.1 67
Table A.2Drift Specifications for 6000 Watt units (10V to 60V Models)
Models 10–600 20–300 30–200 40–150 60–100
Drift (30 minutes):
1
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
4mV
3600 mA
8mV
1800 mA
12 mV
1200 mA
16 mV
900 mA
24 mV
600 mA
Drift (8 hours):
2
Voltage (0.02% of Vmax)
Current (0.04% of Imax)
2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
2mV
240 mA
4mV
120 mA
6mV
80 mA
8mV
60 mA
12 mV
40 mA
Temperature Coefficient:
3
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
3. Change in output per °C change in ambient temperature, with constant line and load.
4mV
360 mA
8mV
180 mA
12 mV
120 mA
16 mV
90 mA
24 mV
60 mA