OVLYLIB=
Description The DDname used to select Forms overlay definitions
Range/Options
OVLY38PP
| 1-8 character DDname reference.
Notes This library reference is only used in conjunction with XES forms.
PAPER=
Description This keyword defines the paper size available in the target printer.
The supplied paper size selection is used to indicate the paper size,
and is used for formatting data, page rotation (when specified). In-
correct specifications of paper size may produce incorrectly format-
ted output. size.
Range/Options
A4
| LETTER | A3 | LEGAL | EXECUTIVE | MONARCH | COM10 |
DL | C5
Notes The supplied paper size is used to format the print data. If this value
does not match the installed paper in the printer, incorrect output may
be produced.
PRMODE=
Description This keyword defines the which JCL PRMODE will be used to indi-
cate that XES to AFP conversion is required, size.
Range/Options
XES
| 1-8 character name.
Notes If this keyword is omitted, the default value of PRMODE=XES will be
used to (for output selection).
TRACE=
Description Activates a program trace (using the supplied trace option). Trace
output is directed to the target specified in the LOGDD keyword.
Multiple trace options may be supplied.
Range/Options
OFF | IO | FLOW | HEX | JOB | ALLOCATE | FSI | WTO | ALL
Notes Care should be taken that sufficient DASD space is allocated when
writing to a file (otherwise a wrap condition will occur). Multiple trace
options can be specified with successive TRACE keywords.
The JOB option records print job stop/start actions. The OFF option
disables tracing. IO traces program input/output. FLOW traces pro-
gram flow. ALLOCATE traces memory utilization and
allocations/deallocations. HEX traces all input data in hexadecimal.
FSI traces JES FSI calls and return codes. WTO includes operator
WTO's in the trace data. TRANS traces the input and output
datastream to and from the XES to AFP transform.
XESLIB=
Description The DDname used to select XES Forms
Range/Options
XESLIB
| 1-8 character DDname reference.
Notes This library reference is only used in conjunction with XES forms.
26 ida XFC Installation Guide