XES530W RELDS REJECTED,RC = xx
Description An error in the JES to IDAXFC FSA interface has occurred.
Severity Processing for the named printer is terminated.
Action Restart the idaXFC specifying an FSI trace option on the failing
printer and contact the product distributor. Return code information
can be found in the appropriate documentation for the FSI macro.
•
XES531I DATASET FREE CALLED WITH FLAG xx
Description Trace information record indicating dataset being released.
Severity Information only message.
Action None.
•
XES532I KEY = nn, NUMBER OF KEYS = nn
•
XES532I nnnnnnnnnnnnnnnnnnnnnnnnnnnnn
Description Trace information record indicating all print job details.
Severity. Information only message.
Action None.
•
XES533I NOTIFY USER ENTERED
Description Trace message.
Severity TRACE message.
Action none.
•
XES534I jobid COMPLETED ON prtid
Description The job name jobid has completed printing on printer prtid. Message
is produced as a result of the JCL NOTIFY option.
Severity Information only message.
Action None.
•
XES535I jobid PLACED ON HOLD BY prtid REASON CODE = rc
Description The job name jobid has not printed and is placed on hold for printer
prtid. Message is produced as a result of the JCL NOTIFY option.
Severity Printing of job did not complete.
Action Examine accompanying messages and error logs to determine the
cause of failure. Release the job from hold if required, when the
problem is corrected (or resubmit the job correctly).
•
XES536W RC FROM SSIREQ = rr
Description An internal processing error has occurred during a sub system inter-
face request.
Severity A severe program error has occurred.
Action Contact the product distributor with a description of the problem.
Appendix A. idaXFC Messages and Codes A-21