Xerox D63-069-00 Copier User Manual


 
XES250I LOGMSG FOR user JOBID= number JOBNAME name
Description Trace information message indicating User, filename, type and
printer.
Severity Information only message.
Action None.
XES251W LOG DATASET FAILED ON printer
XES252W LOG DATASET FAILED ON printer
Description An error has occurred with the LOG dataset associated with the
named printer.
Severity Use of the specified log dataset is terminated. Error logging will be
directed to the target printer.
Action Ensure that the dataset attributes and size of the log dataset are ac-
ceptable, and restart the printer in order to reaccess the log dataset.
XES260W DYNALLOC RETURN rrrr ON PRINTER printer
XES260W INFO CODE rrrr ON PRINTER printer
Description An error occurred for the named printer during a dynamic allocation
operation. The named printer uses dataset file output.
Severity Generation of the file output is terminated.
Action Examine the return code supplied in the INFO CODE using the ap-
propriate IBM Authorized Assembler Programming Guide for an ex-
planation regarding this error. Perform the described corrective
actions to resolve this problem.
XES500W FSA CONNECT REJECTED ON printer, RC =rc
Description Connection of the named printer was not possible.
Severity Processing for the named printer is terminated.
Action Restart the idaXFC specifying an FSI trace option on the failing
printer and contact the product distributor. Return code information
can be found in the appropriate documentation for the FSA macro.
XES501W INTERNAL ERROR DEQ PENDING FOR printer
Description A internal error has been encountered for the named printer.
Severity Processing for the printer FSA is terminated.
Action Restart the printer if required. If this problem persists, contact the
product distributor.
A-16 ida XFC Installation Guide