XES068I PRINTER prtid IS NOT DEFINED
•
XES074I PRINTER prtid IS NOT DEFINED
•
XES081I PRINTER prtid IS NOT DEFINED
•
XES083I PRINTER prtid IS NOT DEFINED
Description An attempt was made to perform an operator command on a printer
that is not defined to this idaXFC.
Severity Processing continues, the command is not performed.
Action Verify that the printer id or idaXFC service machine is correct and re-
specify the command if required.
•
XES069I DUPLICATE PRINTER NAME printer
Description The idaXFC PRINTER name has previously been defined.
Severity The first definition of the PRINTER name will be used.
Action Remove the duplicate printer definition, or modify the printer name to
the correct value.
•
XES070I NO PRINTER SPECIFIED IN ADD COMMAND
Description A dynamic printer addition has not been performed due to an error in
the ADD command (printer not specified).
Severity The additional printer is not added.
Action Respecify the ADD printer command.
•
XES071I IDA XFC NOT LICENSED FOR MORE PRINTERS
Description The total number of printers defined in the
idaXFC
PROFILE exceeds
the maximum allowed by the defined KEY.
Severity The idaXFC terminates.
Action You have attempted to define more printers (that exceed the number
permitted by your key license). If you wish to add additional printers,
an upgraded product key will be required. Operation of
idaXFC
can
be performed by reducing the number of PRINTER statements in the
idaXFC
PROFILE.
•
XES073W FSS CONNECT REJECTED,RC = rc
Description Attachment of the idaXFC FSS to the spool subsystem failed.
Severity idaXFC processing is terminated.
Action Restart the idaXFC specifying an FSI trace option on the failing
printer and contact the product distributor. Return code information
can be found in the appropriate documentation for the FSI macro.
•
XES076I IDA PRINT SUBSYSTEM VERSION version
Description Response to the operator Q SYS LEVEL command.
Severity Information only message.
Action None.
Appendix A. idaXFC Messages and Codes A-9