XES029I DUPLICATE PRINTER NAME prtname
Description An attempt to dynamically add additional printers failed due to a du-
plicate printer name.
Severity The IDAXFC ADD PRINTER command was not performed.
Action Ensure that the additional printer name does not conflict with and ex-
isting printer name and reenter the IDAXFC Add Printer command.
•
XES030I YOU HAVE REACHED MAX NUMBER OF PRINTERS
Description The maximum number of printers that can be defined has been ex-
ceeded.
Severity The idaXFC continues processing using the first 2200 printer (MVS)
or 128 (VM) definitions.
Action Remove additional printer definitions to the allowable maximum. For
MVS, define additional FSS subsystems if more than 2200 printers
are required. For VM, define additional GCS subsystems if more than
128 printers are required.
•
XES032I INVALID TRACE OPTION tracetype
Description The idaXFC profile TRACE option is invalid.
Severity The idaXFC continues.
Action Correct the idaXFC TRACE subparameter option.
•
XES033I INVALID PAPER SELECT command
Description The idaXFC profile PAPER keyword contained an invalid numeric
value.
Severity The idaXFC continues using the default for the named value.
Action Correct the idaXFC subparameter to include a valid numeric value.
•
XES034I BLANK NOT ALLOWED IN text
Description The supplied idaXFC profile keyword cannot be defaulted.
Severity Processing will continue and this statement is ignored.
Action Correct the incorrect idaXFC profile keyword, by supplying a value or
omitting this keyword (use of default).
•
XES050I IDA XFC IS NOT IN PPT. KEY = nn
Description The idaXFC has not been defined in the MVS Program Properties
Table.
Severity Program execution is halted immediately.
Action Ensure that a correct PPT entry exists prior to restarting the idaXFC.
A-6 ida XFC Installation Guide