XES231W GETREC FAILED, RC=
Description An internal idaXFC error occurred.
Severity Processing for the named printer is terminated.
Action Restart the idaXFC specifying an FSI trace option on the failing
printer and contact the product distributor. Return code information
can be found in the appropriate documentation for the FSI macro.
•
XES232I GETREC, FLAGS1=
Description Information message.
Severity Processing continues.
Action None.
•
XES233W GETREC FAILED, FLAGS1=
Description The idaXFC was unable to read the spool volume. A spool IO error
has occurred.
Severity Processing for the named printer is terminated.
Action Verify the integrity of the spool volume, and take any necessary in-
stallation defined recovery actions.
•
XES234I RECORD READ xxxx,xxxx
Description Trace information message.
Severity Processing continues.
Action None.
•
XES235I IDXFLAG1 =
Description Trace information message.
Severity Information only message.
Action None.
•
XES236W FREEREC FAILED, RC=
Description An internal idaXFC error occurred.
Severity Processing for the named printer is terminated.
Action Restart the idaXFC specifying an FSI trace option on the failing
printer and contact the product distributor. Return code information
can be found in the appropriate documentation for the FSI macro.
•
XES237W dataset member READ FAILED
Description The named dataset member contained an invalid record format.
Severity The output job producing the error is held and processing continues.
Action Validate that the input data record format is acceptable and that the
input data has not been corrupted.
Appendix A. idaXFC Messages and Codes A-15