XEROX DOCUPRINT 180 LPS OVERVIEW
XEROX DOCUPRINT 180 LASER PRINTING SYSTEM PRODUCT GUIDE 1-9
Electrical requirements
Table 1-4 shows the electrical requirements for the Xerox DocuPrint
180 LPS.
Note: For more information on Xerox DocuPrint 180 LPS electrical
requirements, including power cord and outlet specifications, refer to
the
Xerox DocuPrint 180 LPS Installation Planning Guide
.
Table 1-4. DocuPrint 180 electrical requirements
Electrical requirements
Printer Dual cord system (60Hz):
Cord 1: 120/208 VAC(182V to 220V) (2 phase), 50 amp dedicated service
Cord 2: 120/208 VAC(182V to 220V) (2 phase), 30 amp dedicated service
Single cord system (50Hz):
WYE: 80/400/415 VAC (3 phase, 5 wire), 20 amp dedicated service
Delta: 220/230/240 VAC (3 phase, 4 wire), 30 amp dedicated service
KVA rating: 7.3 (operating)
System Controller U.S. and Canada, 60 Hz:
208/240 VAC (1 phase) or 208/220 VAC (Line 1 to Line 2);
15 amp service
NEMA 6-15R or ANSI C73, 20R
KVA 1.1 (operating)
International, 50 Hz:
200/230 VAC (1 phase)
15 amp service;
Power connector per local codes
Optional Peripheral Cabinet U.S. and Canada, 60Hz:
208/240 VAC (1 phase) or
208/220 VAC (Line 1 to line 2);
15 amp service;
NEMA6-15R or ANSI C73, 20R
KVA .9 in both standby and operation
International, 50 Hz:
200/230 VAC (1 phase);
15 amp service;
Power connector per local codes
Optional bypass transport The power requirements for the bypass transport module are all satisfied by the
DocuPrint 180 LPS printer module.
Agency certification UL, CSA, IEC, VDE