Zebra Technologies EPL2 Printer User Manual


 
TS Command - Set Real Time Clock
Description Use this command to set the time and date in
printers equipped with the Real Time Clock op
-
tion.
Syntax TSp
1
,p
2
,p
3
,p
4
,p
5
,p
6
Parameters p
1
= Month
Range: 01 to 12
p
2
= Day
Range: 01 to 31
p
3
= Year
Last two digits of Year (e.g. 95)
Range: Years 1991- 1999 = 90-99
Years 2000- 2090 = 00-89
p
4
= Hour in 24 hour format
Range: 00 to 23
p
5
= Minutes
Range: 00 to 59
p
6
= Seconds
Range: 00 to 59
Example:
TS01,01,95,01,00,00 : sets the date to Jan. 1, 1995
: and the time to 1:00 a.m.
TS12,31,01,15,31,00 : sets the date to Dec. 31, 2001
: and the time to 3:31 p.m.
3-88