Zebra Technologies EPL2 Printer User Manual


 
Using AIM Specified
MaxiCode Data
Formatting
The EPL printer can use and automatically de
-
code the AIM ITS (International Technical Stan
-
dards) MaxiCode data format. The printer
detects the message/start header ([)>R
S
), field
separator (G
S
), and the end of message marker
(R
S
E
OT
) data control strings.
The hexadecimal (ASCII) data control strings
are in the following table. See the EPL2 dump
mode character map in Appendix A.
Control String Hexadecimal Code
Message/Start Header
[ ) > R
S 5B 29 3E 1E
Field Separator
G
S 1D
End Of Message Marker
R
S
E
OT 1E 04
Syntax bp
1
,p
2
,M,p
4
“[AIM MaxiCode Data]”
Example
b20,400,M,m2”001,840,93065,1692,[)>R
S
01G
S
98XXXZZFDAAFG
S
SHIPG
S
309G
S
G
S
1/1G
S
10G
S
NG
S
G
S
CAMARILLOG
S
CAG
S
R
S
E
OT
!!!!!!!!!!!!!!!!!!!!!!!”
¿
Notes:
1) This programming example represents actual data used to
format a single AIM compliant MaxiCode symbol as pro
-
grammed by a major international and domestic shipping com
-
pany.
2) The shipper has explicitly set the MaxiCode symbol for Mode
2. This can be omitted by the programmer and the printer will
auto-select the mode per the rules on page 3-16.
3) The shipper has used the "!" character to pad the symbol's
data. A scanner reads back all the "Data" within the quotation
marks, including the "!" characters following the End Of Mes
-
sage Marker (E
OT
).
4) All of the data fields in the Low Priority Message are not
used in the example. Some are left empty with the field delim
-
iting G
S
character used as a format field holder.
980352-001 Rev.A