C Command - Counter
Description The counter (C) command defines one of 10
automatic counters used in consecutive num
-
bering applications (i.e. serial numbers). Coun
-
ters must be defined after variables.
For Numeric Serialization Only. The counter
function does not support Alpha or Alpha-Numeric
Serialization.
Syntax Cp
1
, p
2
, p
3
, p
4
, “[-]PROMPT”
Parameters p
1
= Counter number. Range: 0 to 9
p
2
= Maximum number of digits for the counter.
Range: 1 to 29
p
3
= Field Justification.
L = Left R = Right
C = Center N = No Justification
p
4
= Step Value. + or - sign followed by a
single digit of 1-9. Using a step value of
+0 allows the counter to be used as an
additional variable data field.
“PROMPT”= An ASCII text field that will be
transmitted to the KDU or host (via the
serial interface) each time the command
is executed. Typically used to request the
operator to enter a starting counter value.
KDU Prompt
Options
[-] = Having the first character of the prompt
a single minus sign will cause the
prompt to display only once after form
retrieval.
980352-001 Rev.A