ZyXEL Communications 2864 Network Card User Manual


 
15–6
n=2 Error correcting mode is enabled, handled by
the DCE alone, including buffering of partial
pages.
+FET=n End of page or document command:
n=0 More pages; same document.
n=1 End of document; another document follows.
n=2 No more pages or documents.
n=4 Procedure interrupt; another page follows.
n=5 Procedure interrupt; end of document, another
document follows.
n=6 Procedure interrupt; end of document.
+FK Regular fax abort command.
+FLID="
string
" Local ID string parameter.
+FLO=n Flow control options:
n=0 No flow control.
n=1 Sets XON/XOFF software flow control.
n=2 Sets CTS/RTS hardware flow control.
+FLPL=n Document for polling command:
n=0 The DTE has no document available for polling.
n=1 Indicates that a document is available for polling.
+FMDL? Requests the DCE model identification.
+FMFR? Requests the DCE manufacturer identification.
+FMINSP=n Minimum phase C speed parameter:
n=0 2400 bps.
n=1 4800 bps.
n=2 7200 bps.
n=3 9600 bps.
n=4 12000 bps.
n=5 14400 bps.
+FPHCTO=
<value>
0-255 DTE Phase C response timeout:
Determines how long the DCE will wait for a
command after reaching the end of data when
transmitting in Phase C.
<value>=0 to 255; 100 ms units.
+FPTS=n Page transfer status:
n=1 Received page is good.
Command
Value Description