5–8
If a connection has been made, the LCD will display the actual connected status.
These are data state screens:
On-line Status Screen 1
On-line Status Screen 2
On-line Status Screen 3
Status Display Unit/Meaning
Link Option V34 V.34
Line Speed 28800 bps
Error control V42b V.42bis
Line Type DL Dial-up Line
Data Format AS ASynchronous
Instant Transmission Throughput 55820 bps; Blank in synchronous mode
Instant Receiving Throughput 51324 bps; Link Speed in synchronous
mode
Status Display Unit
Signal to Noise ratio 30.9 dB
Receiving Signal level -25.1 dBm
Phase Jitter in received signal 0.4 degrees
Frequency Offset in received signal -0.0 Hz
Status Display Unit
Retrain Granted 0
Retrain requesTed 0
Round trip Echo Delay 128 T; 1/2400 s
Carrier Loss counts 0
V.34 28800 V42b DL
H>> 55820 51324 AS
<RIGHT>
<RIGHT>
<LEFT>
<LEFT>
<< SN= 30.9 RX=-25.1 >>
PJ= 0.4 FO=-0.0
<< RG= 0 RT= 0 >>
ED = 128 CL= 0
<RIGHT>
<LEFT>
<< FG= 0 FR= 0
BR= 0 FE= 0
<RIGHT>