Basic System Configuration and Management Commands 347
end_time: Enter the end time of summer time, in the format HH:MM:SS.
end_date: Enter the end date of summer time, in the format YYYY/MM/DD.
offset_time: Enter the offset time, that is the amount of time added, in the
format HH:MM:SS.
Description
Use the clock summer-time command to set the name, start date and time, and
end date and time of summer time.
Use the undo clock summer-time command to cancel the currently configured
summer time.
Use the display clock command to check the summer time settings.
Related command: clock timezone
Example
To set the summer time for zone 2 to start at 06:00:00 on 08/06/2002, and end at
06:00:00 on 01/09/2002, with a time added of one hour, enter the following:
<SW4500>clock summer-time z2 one-off 06:00:00 2002/06/08 06:00:00
2002/09/01 01:00:00
To set the summer time for zone 2 to start at 06:00:00 on 08/06, and end at
06:00:00 on 01/09 in each year starting in 2002, with a time added of one hour,
enter the following:
<SW4500>clock summer-time z2 repeating 06:00:00 2002/06/08 06:00:00
2002/09/01 01:00:00
clock timezone Syntax
clock timezone zone_name { add | minus } HH:MM:SS
undo clock timezone
View
User view
Parameter
zone_name: Enter the name of the time zone, up to 32 characters in length.
add: Specifies that time is ahead of UTC.
minus: Specifies that time is behind UTC.
HH:MM:SS: Enter the time difference between the time zone and UTC.
Description
Use the clock timezone command to set local time zone information.