3Com 4500 PWR 50-PORT Switch User Manual


 
Ethernet Port Configuration Commands 51
Description
Use the command interface interface_type interface_number to enter the
interface of the specified port.
If you want to configure the parameters of an Ethernet port, you must first use
this command to enter the Ethernet port view.
Example
To enter the interface for port “Ethernet1/0/1”, enter the following:
<4500>system-view
System View: return to User View with Ctrl+Z.
[4500]interface ethernet1/0/1
[4500-ethernet1/0/1]
loopback Syntax
loopback { external | internal }
View
Ethernet Port View
Parameter
external: External loop test.
internal: Internal loop test.
Description
Use the loopback command to configure the Ethernet port to perform the
loopback test to check if the Ethernet port works normally. The loop test will finish
automatically after being performed for a while.
By default, the Ethernet port will not perform the loopback test.
Example
To perform the internal loop test for Ethernet1/0/1, enter the following:
<4500>system-view
System View: return to User View with Ctrl+Z.
[4500]interface ethernet 1/0/1
[4500-Ethernet1/0/1]loopback internal
#Apr 2 02:46:02:29 2000 4500 L2INF/2/PORT LINK STATUS CHANGE:- 1 -
Trap 1.3.6.1.6.3.1.1.5.4: portIndex is 4227626, ifAdminStatus is 1,
ifOperStatus is 1
%Apr 2 02:46:02:225 2000 4500 L2INF/5/PORT LINK STATUS CHANGE:- 1 -
Ethernet1/0/1: is UP
%Apr 2 02:46:02:342 2000 4500 STP/2/SPEED:- 1 -Ethernet1/0/1's
speed changed
!
#Apr 2 02:46:02:521 2000 4500 L2INF/2/PORT LINK STATUS CHANGE:- 1
-Trap 1.3.6.1.6.3.1.1.5.3: portIndex is 4227626, ifAdminStatus is 1,
ifOperStatus is 2