3Com NETBuilder SI Network Router User Manual


 
86 CHAPTER 7: ADVANCED CONFIGURATION OF PORTS AND PATHS
Configuring Dial-Up
over PPP with
Modems or TAs
This section describes two dial-up scenarios:
Scenario 1: Single Destination per Port
Scenario 2: Multiple Destinations
ISDN TAs If you are using both B channels together for a 128 Kbps connection,
each TA used at each end of the connection must support the same B
channel aggregation protocol: Multilink PPP or bonding.
You cannot use each B channel independently on an external ISDN TA.
Scenario 1: Single Destination per Port
This scenario shows a model 44x bridge/router connecting to one
destination on each serial port.
Start here
Done
128 K
28.8 K
1-510-555-9876
Create the dial number list for ports 5 and 6:
ADD !5 -PORT DialNoList "1-408-555-7000" Baud = 128 Type = Bri
ADD !6 -PORT DialNoList "1-510-555-9876" Baud = 28.8 Type = Modem
Set the normal bandwidth for ports 5 and 6:
SETDefault !5 -PORT NORMalBandwidth = 128
SETDefault !6 -PORT NORMalBandwidth = 28.8
!6
!5 (path)
1-408-555-7000
!5
!4 (path)
NETBuilder/II
®
Each Serial port connects to
one destination.
Model 44x
TA
TA
Modem
Modem
Syntax: SETDefault !<port> -PORT NORMalBandwidth = <kbps> (>=0)
ADD !<port> -PORT DialNoList "<phone no>" [Baud = <rate> (1.2–16000)]
[Type = Modem | Bri | Sw56] [Pos = <number>]
Syntax: