3Com 6200 Switch User Manual


 
3COM Security Switch 6200 Hardware and Software Users Guide 3-3
Interface Connections and First Time Start-Up
Connecting Remotely
To access the system remotely:
1. Connect one end of an RJ45-to-RJ45 cable into a remote access device.
2. Connect the other end into the Management port. Figure 3-2 shows the
Management port module connected to a hub.
Figure 3-2 Connecting to the System Remotely
3. Telnet to configure IP.
Power
Connections
CAUTION: To ensure power connectivity, if you are using more than one
power supply, be sure to use separate power sources.
To connect power cabling:
1. Place the female end of the power cable into the power supply
connector located on the back of the chassis. Refer to Figure 3-3 for
the exact location.
Figure 3-3 System Rear View Power Connections
NOTE: Before applying power to the system, be sure you have
connected a terminal or PC to the craft port. This allows you enter
commands needed at startup.
Hub
Primary Power
Supply Connection
Secondary Power
Supply Connection
Power Supply Audible
Alarm Reset Button