Installing the Switch 1000
Rack Mounting
The Switch is 1.5U high and fits in most standard
19-inch racks.
CAUTION: Disconnect all cables from the Switch
before continuing. Remove all self adhesive pads
from the underside of the unit, if fitted.
1
Place the unit the right way up on a hard flat sur-
face, with the front facing towards you.
2
Locate a mounting bracket over the mounting
holes on one side of the unit, as shown in
Figure 2-2.
Figure 2-2
Fitting a bracket for rack mounting
3
Insert the three screws and fully tighten with a suit-
able screwdriver.
4
Repeat steps 2 and 3 for the other side of the unit.
5
Insert the unit into the 19-inch rack and secure with
suitable screws (not provided). Ensure that ventila-
tion holes are not obstructed.
6
Connect network cabling.