4-18 EXTENSA 700/710 Service Guide
The right corner screen information gives you the available function keys and
the specified test number.
• Space Enables/disables the item
• ESC Exits the program
• F1 Help
• F2 Tests the selected item(s)
• Enter Opens the available suboptions
• Test Times Indicates the number of tests to perform.
Note: The F1 and F2 keys function only after you finish configuring the
Test option.
PQA Diagnostic Program Error Code and Messages
\
Error Code Message Spare Part/Action in Sequence
System
16XX Backup battery error Backup battery
1XXX CPU or Main board error 1. Reload BIOS default setting.
2. CPU
3. Main board
2XXX Memory error 1. Reseat CPU(IMM module)
2. DIMM
3. Main board
3XXX Keyboard error 1. Reseat Keyboard
2. Keyboard
3. Main board
4XXX Video error 1. Main board
5XXX Parallel Port error 1. Main board
6XXX Serial port or Main board
error
1. Main board
7XXX Diskette drive error 1. Diskette drive
2. Main board
8XXX Hard disk error 1. Reload BIOS default setting.
2. Hard disk
3. Main board
9XXX CD-ROM error 1. Reseat CD-ROM cable
2. CD-ROM drive
3. Main board
10XXX CPU or Main board error 1. CPU
2. Main board
11XXX Pointing device error 1. Reseat Keyboard
2. Keyboard
3. Main board
700SG-4.fm Page 18 Thursday, May 28, 1998 1:13 PM