ADC Campus-REX RS Interface Card Network Card User Manual


 
Monitoring with an ASCII Terminal
Campus-REX RS Interface Card User Manual 6-3
2 Type then press . The Current System Status menu displays.
The Current System Status menu provides the following information:
Local Alarms indicates the current local alarm status
Remote Alarms indicates the current remote alarm status
Loopback indicates the current loopback status
Margin indicates the minimum (mn), current (cr), and maximum (mx)
HDSL margin value, measured in dB, relative to the signal-to-noise ratio
required for a Bit Error Rate (BER) of 10
-7
Pulse Attn indicates the decrease in amplitude of the transmitted signal
as measured at the HDSL receiver
24 Hour ES indicates the number of errored seconds over the last
24 hours
24 Hour UAS indicates the number of unavailable seconds over the last
24 hours
Last Cleared indicates the date and time when the error counter was last
cleared
1 ENTER
May 3, 1999 ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx 13:14:35
Local Unit ID: Campus-REX Unit #34 Local I/F: REX
Remote Unit ID: Campus-REX Unit #12 Remote I/F: REX
Circuit ID: Network Extension Circuit 5001
CURRENT SYSTEM STATUS
Local Alarms:
Remote Alarms:
Loopback: None
HDSL-A HDSL-B
LOCAL REMOTE LOCAL REMOTE
-------- -------- -------- --------
mn/cr/mx mn/cr/mx mn/cr/mx mn/cr/mx
Margin (dB): na/na/na na/na/na na/na/na na/na/na
Pulse Attn (dB): 00 00 00 00
24 Hour ES: 00000 00000 00000 00000
24 Hour UAS: 05671 00000 05671 00000
Last Cleared: None
(U)pdate (C)lear
(R)eturn (M)ain Menu
ENTER CHOICE>
CAD1069i5.book Page 3 Thursday, May 30, 2002 7:32 AM