Configuring with an ASCII Terminal
5-8 Campus-REX RS Interface Card User Manual
2 Type then press . The SNMP Configuration menu displays.
3 Continue with the following sections to enter the required parameters
and, if desired, enable authentication error trap generation.
Entering Required SNMP Parameters
To set the required parameters:
1 From the SNMP Configuration menu, type then press . The
system prompts you to enter the Read Only Comm String.
2 Type Public, or another string of up to 32 characters then press .
The SNMP Configuration menu displays.
3 Type then press . The system prompts you to enter the Read
Write Comm String.
4 Type Private, or another string of up to 32 characters as prompted then
press . The SNMP Configuration menu displays.
2 ENTER
May 3, 1999 ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx 13:18:03
Local Unit ID: Campus-REX Unit #34 Local I/F: REX
Remote Unit ID: Campus-REX Unit #12 Remote I/F: REX
Circuit ID: Network Extension Circuit 5001
SNMP CONFIGURATION
1) SNMP Read Only Community String: public
2) SNMP Read/Write Community String: private
3) Authentication Trap Status: Disabled (Disabled, Enabled)
4) Trap Receiver 1 IP Address: 0.0.0.0
5) Trap Receiver 1 Community String: public
6) Trap Receiver 2 IP Address: 0.0.0.0
7) Trap Receiver 2 Community String: public
(R)eturn
ENTER CHOICE>