Set Up the Campus-REX System
Campus-REX RS Interface Card User Manual 3-9
1 If the Operating Mode is set to Standard Mode, proceed to Step 3.
Otherwise, press Enter.
2 Press Next until the LCD displays STANDARD, then press Enter. The
Operating Mode changes to Standard.
3 Press Next until HDSL RATE displays, then press Enter.
4 Press Next until the desired HDSL transmission rate displays, then
press Enter.
To continue setting up the system, proceed to “Configure the Campus-REX
as a Bridge or Router” on page 3-19.
Extended HDSL Mode
This section continues from Step 4 in “Using the LCD” on page 3-8 to set the
Extended Mode parameters.
To set an Extended Mode HDSL Rate, you must:
• Set the Extended Mode Loop Configuration to 1 Loop or 2 Loop,
depending on the physical layout of your HDSL network.
• Set the Extended Mode HDSL Rate to one of the options determined by
the Extended Mode Loop Configuration:
– 1 Loop HDSL Rate settings are between 128 kbps and 1.152 Mbps,
in 64 kbps increments.
– 2 Loop HDSL Rate settings are between 256 kbps and 2.304 Mbps,
in 128 kbps increments.
1 With the LCD displaying OPERATING MODE, press the Enter button.
2 Press Next until EXTENDED displays, then press Enter. The LCD
displays OPERATING MODE.
3 Press Next two times. LOOP MODE displays.
4 Press Enter.
5 Press Next until the desired Loop Mode setting displays, then press
Enter. The LCD displays LOOP MODE.
CAD1069i5.book Page 9 Thursday, May 30, 2002 7:32 AM