Table 1-2. Supplemental Characteristics (continued)
Agilent Model
Parameter 66101A 66102A 66103A 66104A 66105A 66106A
Trigger Response Time (average time
for the output voltage or current to
begin to change upon receipt of an
external trigger)
With GPIB activity: 5 ms
Without GPIB activity: 3 ms
Trigger Maximum Frequency (for
repetitive external triggering, the
maximum frequency for which the
Trigger Response Time is valid)
With GPIB activity: 75 Hz
Without GPIB activity: 85 Hz
Dwell Time
Programmable range: 10 ms to 65 s
Resolution: 2 ms
Accuracy
With GPIB activity:
±
5 ms
Without GPIB activity:
±
2.5 ms
Downprogramming:
Active downprogrammer sinks approximately 10% of rated output current
Monotonicity:
Output is monotonic over entire rated voltage, current, and temperature range
GPIB Interface Capabilities
Interface Signals (see IEEE 488.1): AH1,C0,DC1, DT1,EI,LE4,PP0, RL1,SH1,SR1,TE6
Programming Language: SCPI (Standard Commands for Programmable Instruments)
Serial Link Capabilities (maximum
power modules sharing one GPIB
primary address)
16
Savable States
10
Nonvolatile memory locations: 5 (0 through 4)
Volatile memory locations: 5 (5 through 9)
Nonvolatile memory write cycles: 40,000 (typical)
Recommended Calibration Interval:
1 year
Safety Compliance
Complies with: CSA 22.2 No.231 & IEC 348
Designed to comply with: UL 1244 & VDE 0411
RFI Suppression (designed to comply
with):
FTZ 1046/84, Level B
Dimensions
Width: 48.3 mm (1.9 in)
Height: 141.2 mm (5.6 in)
Depth
Pull tab inserted: 571.4 mm (22.5 in)
Pull tab extended: 606.4 mm (23.8 in)
Weight
Net: 2.7 kg (6 lb)