Allied Telesis AR700 Series Switch User Manual


 
Hardware Reference 45
C613-03087-00 Rev E
LEDs
AC power supply
•RPS fan fault
•Router PSU fault
RPS PSU fault
Main (router) fan fault
AC Power Supply
Universal 110 VAC to 240 VAC, 50 Hz to 60 Hz input
DC Output
5 V/6.5 A
12 V/1.0 A
-12 V/0.2 A
AR740 RPS LEDs and
what they mean
LEDs on the rear panel indicate the RPS’s operational status.
Table 7: AR740 RPS LEDs
LED State Function
Power Green The RPS unit is receiving AC power and the
voltage is within an acceptable range.
RPS Fan Fault Amber The RPS is switched OFF.
Mains power to the RPS has failed.
An RPS fan has failed.
Off Normal operation.
Main PSU Fault Amber The corresponding router is switched OFF or its
PSU has failed.
Mains power to the router has failed.
The DC cable between the router and RPS is
not connected.
The RPS is supplying power to the router.
Off Normal operation.
RPS PSU Fault Amber The RPS is switched OFF or its PSU has failed.
Mains power to the RPS has failed.
The DC cable between the corresponding
router and RPS is not connected.
Off Normal operation.
Main Fan Fault Amber The DC cable between the corresponding
router and RPS is not connected.
A main router fan has failed.
Off Normal operation.