1) Clock Source
00h: Internal
01h: External
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
224 (E0h) Parameter Error: Invalid clock source
238 (EEh) Time Out Error
Set T1/E1 Pattern – Control Word (A003h) (Option 50 only)
Description: Sets the data pattern of T1/E1 measurement mode.
Bytes to Follow: 2 bytes
1) Data Pattern
00h: AUTO_DETECT
01h: PRBS_9
02h: PRBS_11
03h: PRBS_15
04h: PRBS_20 (O.151)
05h: PRBS_20 (O.153)
06h: PRBS_23
07h: QRSS
08h: ONE_IN_8
09h: TWO_IN_8
0Ah THREE_IN_24
0Bh: ALL_ONES
0Ch: ALL_ZEROS
0Dh: T1_DALY
0Eh: BLUE_ALARM
0Fh: YELLOW_ALARM
10h: USER_DEFINED
2) Inverted Pattern Option (01h: Inverted; 00h: Non-inverted)
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
224 (E0h) Parameter Error: Invalid pattern index
238 (EEh) Time Out Error
Set T1/E1 Error Insert Type/Value – Control Word (A004h) (Option 50 only)
Description: Sets the Insertion Error type and the number of errors.
Bytes to Follow: 5 bytes
1) Error Type
00h: Bit
01h: Bert
02h: BPV
03h: Framing
2) Number of Errors (highest byte)
3) Number of Errors
4) Number of Errors
5) Number of Errors (lowest byte)
Site Master Returns: 1 byte
Site Master PM 97