Anritsu S331D Network Router User Manual


 
1) 255 (FFh) Operation Complete Byte
224 (E0h) Parameter Error: Invalid error type or value
238 (EEh) Time Out Error
Set T1/E1 Framing Mode – Control Word (A005h) (Option 50 only)
Description: Sets the Framing Mode of T1/E1 measurement.
Bytes to Follow: 1 byte
1) Framing Mode
00h: Auto
T1 Tester Only
01h: D4 SF
02h: ESF
E1 Tester Only
03h: PCM30
04h: PCM30 CRC
05h: PCM31
06h: PCM31 CRC
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
224 (E0h) Parameter Error: Invalid framing mode
238 (EEh) Time Out Error
Start and Stop T1/E1 Measurement – Control Word (A006h) (Option 50 only)
Description: This command toggles the Run/Stop state of the T1/E1 measurement. That is, if the command is sent while the
measurement is running, the command stops the measurement. If the command is sent when the measurement is stopped, the
command starts the measurement.
Bytes to Follow: 0 bytes
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
238 (EEh) Time Out Error
Insert Error for T1/E1 Measurement – Control Word (A007h) (Option 50 only)
Description: This command inserts the error defined into the data flow.
Bytes to Follow: 0 bytes
Site Master Returns: 1 byte
1) 255 (FFh) Operation Complete Byte
238 (EEh) Time Out Error
Get T1/E1 Pattern – Control Word (A008h) (Option 50 only)
Description: Get the current T1/E1 pattern.
Bytes to Follow: 0 bytes
Site Master Returns: 1 byte
1) T1 Pattern
98 Site Master PM