5.6 Switching on
the HTI lamp
Before switching on the HTI lamp, please ensure that
The Master Control Knob photo is in the ”0” position.
Film is not running in the projector.
1) Depress ”lamp” key for approx. 1 second to ignite the
lamp. During this ignition phase, which lasts approx.
5 seconds, all key functions are disabled.
2) The HTI lamp can be switched off after a reset time of
5 seconds by depressing the ”lamp” key again.
Note: Run-up time to full light power is approx. 40
seconds. Working temperature of the lamp is
reached in three minutes. During this period the
lamp should never be switched off, because this
gradually reduces the life of the lamp and
results in poor ignition behavior.
Initial Operation
master control knob
“lamp“-key
Note: The average life of an HTI lamp
is approx. 750 hours.
Spare lamps can be ordered under
Id.No. 05.09873.0.