ARRI LOCPRO 35 Projector User Manual


 
60
Fault Cause Remedy
Film channel Foreign matter in film channel. Remove obstacle
“OPEN/CLOSE” function disturbed Film loop cannot be formed and actuate “Film” key once again.
Film not properly inserted Tension film slightly on both film plates
with film channel open.
Film must drop totally to bottom of film channel.
Lamp cover not properly seated Check film channel slide on lamp cover
or distorted for easy running. If sluggish, replace
and lock lamp cover with film channel open.
If this fails, call Service Engineer.
Loop sensor dirty; Clean with ARRI maintenance tools.
Reflex light barrier
on left loop box
doesn’t detect film loop.
Electronic board defective Call ARRI Service station
Sudden stop during film transport Film loop monitor switch has detected Open and close film channel. Repeat film transport.
improper splicing or stapled film In case of stapled film remove staples
and replace by splicing.
Then check pressure pad and film guiding elements
for possible damage.
Trouble-Shooting