64
Fault Cause Remedy
E-No. 108 > See E-No. 102 See E-No. 102.
Carriage doesn’t close properly.
Shipping safety screw screwed in Remove shipping safety screw.
E-No. 110 > See E-No. 102 See E-No. 102.
Carriage doesn’t close or closes too slowly.
E-No. 112 > See E-No. 102 See E-No. 102.
as E-No. 108 Dual loop almost completed.
E-No. 114 > Film chips or splicing tape chips in film channel Remove chips, clean film guide parts and remove
Dual loop cannot be completed. or film emulsion deposits emulsion deposits.
on film guide parts.
E-No. 120 > See E-No. 102 See E-No. 102.
Film channel cannot be closed completely.
E-No. 122 > See E-No. 114 See E-No. 114.
Last frame of dual loop
cannot be totally pulled in.
E-No. 124 > Control error. Repeat procedure several times.
Film channel opens again If fault still exists after several attempts
slightly after closing. (indicated by E-No. 124) call ARRI Service station.
Trouble-Shooting