ARRI LOCPRO 35 Projector User Manual


 
66
Fault Cause Remedy
E-No. 148 > Foreign matter in film channel. Open film channel and remove foreign matter.
Feed and take-up motor jamming
during projection. Defective belt. Check winders for turnability.
If they can be turned independently
from each other, call ARRI Service station.
Feed and take-up motor drive jamming. Call ARRI Service station.
Film winding plate jamming. Remove obstacle.
Winding motor defective. Call ARRI Service station.
E-No. 150 > See E-No. 148 See E-No. 148
Feed and take-up motor jamming during rewinding.
E-No. 152 > Lamp cover not placed in position Attach lamp cover or clean actuation opening
Shutter motor not running. or safety switch not actuated. for safety switch.
Revolving shutter jamming because of foreign matter. Remove foreign matter or call ARRI Service station.
Shutter motor defective. Call ARRI Service station.
Video camera defective at video “ON”. Test function with video “off”.
No sync signal for revolving shutter. Otherwise call ARRI Service Station.
Trouble-Shooting