ARRI LOCPRO 35 Projector User Manual


 
25
6.1.5 Autostop Function
In order to prevent the film from unintentionally running
out to the end, the auto-stop feature automatically stops
the film approx. 2 m (6 ft) before the end. This applies to
both film plates.
Note: The auto-stop function is only ensured if the film
core used coincides with the value selected in
mode 4 (”more config” ”bobby size”).
Selectable diameters are 50 (2“), 75 (3“) and
100 mm (4“).
Disabling the Auto-stop Function
To run the film completely through the film channel
without end stop, press the ”Film” Key photo
during projection or high speed shuttle. The frame
counter display flashes, the auto-stop feature is
disabled and the film runs through the film channel
without stopping.
The auto-stop function is reactivated by changing the
direction of film transport with the Master Control Knob.
6.2 Highspeed Shuttle/
Rewinding
By turning the Master Control Knob photo beyond the
highest projection speed to the left or right, the film runs at
a speed of approx. 200 fps in the selected direction.
During this high speed transport mode the film stage is
lifted up by magnets for safer film transport. When
releasing the Master Control Knob, film transport is
reduced to fastest projection speed.
Functions
master control knob
“film“- key