Asante Technologies 5212 Switch User Manual


 
Viewing Statistics
Page 6-9
Counter Description
Pkt128-255 The total number of packets (including
error packets) received that were
between 128 and 255 octets in length
(excluding framing bits, but including
FCS octets).
Pkt256-511 The total number of packets (including
error packets) received that were
between 256 and 511 octets in length
(excluding framing bits, but including
FCS octets).
Pkt512-1023 The total number of packets (including
error packets) received that were
between 512 and 1023 octets in length
(excluding framing bits, but including
FCS octets).
Pkt1024-1518 The total number of packets (including
error packets) received that were
between 1024 and 1518 octets in length
(excluding framing bits, but including
FCS octets).
NetOctets The total number of octets of data
(including those in bad packets) received
on the network (excluding framing bits
but including FCS octets). This object
can be used as a reasonable indication
of Ethernet utilization.
SQEErrors A count of times that the SQE TEST
ERROR message is generated by the PLS
sublayer for a particular interface. The
SQE TEST ERROR is defined in section
7.2.2.2.4 of ANSI/IEEE 802.3 - 1985 and
its generation in 7.2.4.6 of the same.
GoodTXOctets A count of data and padding octets of
frames that were successfully
transmitted.
book Page 9 Monday, March 2, 1998 4:27 PM