ATEN Technology KH2508 Switch User Manual


 
Chapter 5. The Firmware Upgrade Utility
65
Upgrade Failed
If a device fails to complete the upgrade successfully, start the firmware
upgrade procedure again. If the KH2508 / KH2516 becomes inoperable after a
failed firmware upgrade, follow the Firmware Upgrade Recovery procedure
below.
Firmware Upgrade Recovery
If the firmware upgrade procedure is unnaturally aborted (due to a power
outage, for example), the KH2508 / KH2516 that was being upgraded at the
time may become inoperable, and may be incapable of accepting a normal
firmware upgrade. If this occurs to the first level KH2508 / KH2516, do the
following:
Note: To perform a firmware upgrade recovery on a cascaded KH2508 /
KH2516, remove the switch from the installation before performing the
following steps.
1. Prepare the Firmware Upgrade Package (see page 58).
2. Slide the unit's Firmware Upgrade Recovery Switch (see page 7) to the
RECOVER position.
3. Perform a warm reset (see Reset Button, page 7).
The switch is now ready to be upgraded.
Note: When the switch is in Firmware Upgrade Recovery Mode, the front
panel console LEDs alternately flash on and off, and the port LEDs
turn on and off, scrolling from left to right, first green then red.
4. Run the downloaded Firmware Upgrade Package file again.
5. When all devices have been upgraded, click Finish to close the Firmware
Upgrade Utility.
6. Slide the unit's Firmware Upgrade Recovery Switch (see page 7), to the
NORMAL position.
7. Reboot the upgraded KH2508 / KH2516 by turning it off, then on again.
Note: After upgrading a cascaded switch, turn off the switch, return it to
the installation, reconnect all cabling and turn it on.