Appendices 101
Command Function
enable persistent mode
Enables persistent connection mode on a user st
ation
. Every time a connection is
made to a server, the UID of the server and the connection type are stored in
EEPROM. If the connection is lost, these values are used to re-establish the
connection.
disable persistent mode
Disables persistent connection mode. If a connection is lost, ther
e will be no attempt
to try to re-establish it.
show persistent mode
Shows the current persistent connection mode, and if enabled, shows the current
stored U
ID and connection type set
tings.
vcm once (remove vcm
blin
k)
Enables VCM Once mode. This will cause VCM settings for the ne
xt connection to
be stored in EEPROM and used in all subsequent connections. If this command is
executed when VCM is already in this mode, the VCM settings of the next
connection established will replace the existing VCM settings in EEPROM.
vcm always
Disables VCM Once mode and returns the AMX 51xx switch to its normal VCM
mode, where VCM
is performed on every connection established.
vcm status
Shows the current VCM mode and displays the VCM settings currently stored in
EEPROM.
disable auto user login
Clears the currently stored username and password that are stored if the Auto Login
featur
e is enab
led.
enable pod switch
mode
Enables this mode. T
his cannot be done via the OSD if a switch
is not connected.
disable pod switch
mode
Disa
bles this mode. This cannot be done via the OSD if a switch is not connected.
show pod switch mode
Shows the current status of this mode. This cannot be done via the OSD if a switch is
not connected.
enable serial emulation
When serial emulation is enabled, the CPU’
s serial port is disabled (AMX 513
0
switch user station only).
disable serial emulation
When serial emulation is disabled, the CP
U’s serial port is enabled (AMX 5130
switch user station only).
equalization tuning Shows the Equalization Tuning OSD.
deskew tuning
Shows the Deskew Tuning OSD (Only on AMX 5121/5130 switch - based platforms
with skew card).
e
nable serial force
mode
Enables this mode. C
an also be performed via OSD Lockdown Tab, but must be
performed via command line if only local AMIQ modules are connected.
disable serial force
mode
Disa
bles this mode. Can also be performed via OSD Lockdown Tab, but must be
performed via command line if only local AMIQ modules are connected.
Table F.1: Access Commands (Continued)
AMX.book Page 101 Thursday, June 12, 2008 4:14 PM