Connections
5976072 BARCOELM R12 05052000
Possible indication :
RGB-SS [CS or HS&VS] = separate sync is composite sync or horizontal and vertical sync.
RGB-SS [3LSS or CV] = separate sync is composite tri-level sync or composite video.
Fixed 5-Input Slot (slot 2)
Slot 2 has 5 BNC input terminals.
R
G
BH / C V
On
Hi gh Ban dwi dt h RGB ANALOG INPUT
RGB
H / C
V
On
High Bandwi dth 5 CABLE IN PUT
On
COMM PORT TR IG GER OU TRS232/422 OUTRS232/422 IN
I R - Receiv e rDiagnostic Code
Green Operation
Red Sta nd-by
IRSy nc OK
Hardwired
re mo t e
CTRL 1
Hardwired
remote
CTRL 2
Two wa y
hardwired
re mo t e
CTR L 3
Which signals can be connected to slot 2 ?
The following signals can be connected to these BNC connectors:
Connector name R G B H V
Input signal
RGBHV R G B H V
RGBS R G B S -
RGsB R Gs B - -
Composite Video - Video - - -
Super Video - Y - - C
Component Video - SS R-Y Y B-Y S -
Component Video - SOY R-Y Ys B-Y - -
How to select input Slot 2 :
Key in 2 on the RCU or the local keypad.
Selection of the signal format on the 'Input slot' menu.
How to change the input slot setting
1 Press ADJUST or ENTER key to start up the Adjustment mode.
2 Push the cursor key é or ê to select Installation (menu 1)
3 Press ENTER.
4 Press the cursor key é or ê to select 'Input Slots' (menu 2)
5 Press ENTER. The internal system will scan the inputs and displays the result in the 'Input Slots' menu.
6 Push the cursor key é or ê to select the second slot (menu 3).
7 Press ENTER key to toggle the input signal priority.
Select with é or ê
then <ENTER>
<EXIT> to return.
ADJUSTMENT MODE
Select a path from below :
RANDOM ACCESS
INSTALLATION
SERVICE
INSTALLATION
INPUT SLOTS
800 PERIPHERAL
CONFIGURATION
OSD COLOR
INTERNAL PATTERNS
NO SIGNAL
LENS
INPUT SLOTS
Slot Module type [Config]
1. RGB-SS [CV]
2. RGB-SOG
3. Video [Video]
4. Component Video
5. SDI
6. SDI
Select with é or ê
<ENTER> to toggle
<EXIT> to return.
Select with é or ê
<ENTER> to toggle
<EXIT> to return.
menu 1