Barco R9001490 Projector User Manual


 
Service Mode
9-5
5976072 BARCOELM R12 05052000
Select with é or ê
then <ENTER>
<EXIT> to return.
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
LAMP
MORE...
Select with é or ê
then <ENTER>
<EXIT> to return.
Change Projector Address
How to change that address ?
1 Push the cursor key é or ê to highlight 'Change Proj. Address' (menu 1).
2 Press ENTER .
The Change Projector Address menu will be displayed and the actual address will be filled in.
The first digit is highlighted (menu 2).
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
LAMP
MORE...
Select with é or ê
then <ENTER>
<EXIT> to return.
Change Language
Start Up
1 Push the cursor key é or ê to highlight 'Change Language' (menu 1).
2 Press ENTER to display the language selection menu (menu 2).
Available languages : English
menu 1
menu 2
menu 1
menu 2
Select with é or ê
then <ENTER>
<EXIT> to return.
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
LAMP
MORE ...
CHANGE PROJ. ADDRESS
Enter new address
001
Select with ç or è
Reprogram with é or ê
or numeric keys
<ENTER> to confirm
<EXIT> to return
Entering the new projector address.
1 the digit keys on the RCU or the local keypad or
2 use the control disc to the right or to the left to select a digit and change the value by pushing the control disc up or down until the
new value is reached. Continue with the other digits on the same way.
Serial Communication
Start Up the Serial Communication menu
1 Key é or ê to highlight 'Serial Communication' (menu 1).
2 Press ENTER to display the Serial Communication menu (menu 2).
The baudrate, interface standard and termination can be installed.
menu 1
menu 2
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with é or ê
then <ENTER>
<EXIT> to return.
CHANGE LANGUAGE
English