Black Box EncrypTight Enforcement Point (ETEP) Network Hardware User Manual


 
Product Overview
24 ETEP Installation Guide
MIB Support
This section identifies the Black Box MIBs and standard MIBs that are used to manage ETEP appliances.
The MIBs can be loaded into a management station SNMP client application, which typically includes a
MIB browser and an SNMP trap receiver. The SNMP management application uses the MIBs to interpret
the SNMP queries made on the appliance and to interpret SNMP traps generated by the appliance.
The ETEP supports the MIBs listed in Table 11. In some cases MIB objects are supported only to the
extent that they return values when a MIB walk is performed on the appliance. Refer to the MIBs
themselves, which are included on the software CD, for details about the MIB objects and expected
behavior.
To learn more about the traps that the ETEP generates and how to configure them, see the “ETEP
Configuration” chapter in the EncrypTight Manager User Guide.
Table 10 ET10000A Mechanical and Environmental Specifications
Category Specification
Interfaces (2) 10 Gigabit Ethernet ports for encrypting and decrypting traffic
(single mode, multimode, or copper)
10/100 Mbps auto-sensing Ethernet LAN port for management
RS-232C port for management
(3) Auxiliary Gigabit LAN ports (not enabled)
(3) Auxiliary 10/100 Ethernet LAN ports (not enabled)
(1) Gigabit Ethernet port for management (not enabled)
(1) USB port for management (not enabled)
Mechanical Dimensions 19 inch rack mount design
2U tamper evident chassis
Dimensions: 3.5” H x 17” W x 20” D
Weight: 18 pounds
Electrical: AC power supplies Voltage: 90 - 264 VAC Full Range
Frequency: 47 - 63 Hz
Input Current: 6.0 / 3.0 A for 115 / 230 VAC
Inrush Current: 60A / 80A MAX. FOR 115 / 230 VAC Per Power
Module
MAX Input Power: 350W
Electrical: DC power supplies Voltage: DC -36 V - -72 V
Input Current: 12A Maximum for -48VDC
Inrush Current: 20A MAX for each power unit
MAX Input Power: 350W
Environmental Operating temperature: 0 to 40 degrees C (32 to 104 degrees F)
Operating humidity: Up to 90% (non-condensing)
Operating altitude: -200 to 10,000 feet AMSL
Regulatory See “ET10000A Regulatory Information” on page 82.