ETEP Installation Guide 57
3 Initial Setup
Overview
The following steps are required for initial setup of the ETEP:
1 Log in through a serial link.
2 Configure the management port.
3 Set the date and time.
4 Enter the throughput license.
Logging In Through a Serial Link
Initial setup is performed through a serial link to the RS-232 port. The initial setup commands are
available to the Admin and Ops users. The procedures and examples in this chapter assume that the
Admin user is performing the setup tasks.
To log in to the CLI via a serial link:
1 Connect the RS-232 serial port directly to a PC or workstation, as described in Chapter 2.
2 Open a terminal session through a VT-100 terminal emulation program such as HyperTerminal. Enter
the connection name, the appropriate serial port (usually COM1 or COM2), and the following serial
port parameters:
3 In the terminal session window, press ENTER. The login prompt displays.
Linux 2.6.16.17 on mips
pep login:
4 At the login prompt, type the default user name admin and press ENTER. User names and
passwords are case-sensitive.
5 At the password prompt, type the default password
admin and press ENTER.
Baud Speed 38,400
Parity None
Data Bits 8
Stop Bits 1