Black Box EncrypTight Enforcement Point (ETEP) Network Hardware User Manual


 
Installation
28 ETEP Installation Guide
If you are using EncrypTight Manager to manage your ETEPs, you will need to install the EncrypTight
Manager software on the management station to configure the ETEPs for network operation and to create
and deploy policies. See the EncrypTight Manager User Guide for more information about using ETEPs
with the EncrypTight Manager system.
The third party software listed in Table 12 is used when managing the ETEP in a standalone deployment.
See the EncrypTight Manager User Guide for additional third party software you may want to install
when using in EncrypTight Manager to manage Black Box appliances.
ETEP Site Preparation
Most ETEP models can be mounted in a standard 19-inch rack using the supplied mounting kit, or simply
placed on a rack shelf or solid surface. Before installing the ETEP in a 19-inch rack, consider the
following guidelines:
Ambient temperature
Install the ETEP in an environment compatible with the 40ºC maximum recommended ambient
temperature. Extra clearance above or below the unit on the rack is not required; however, be aware
that equipment placed in the rack beneath the ETEP can add to the heat load. Therefore, avoid
installing in an overly congested rack. Air flowing to or from other equipment in the rack might
interfere with the normal flow of cooling air through the ETEP, increasing the potential for
overheating.
Air flow
Make sure that there is sufficient flow of air around the ETEP so that safe operation is not
compromised. Maintain a clearance of at least 3 inches (7.62 cm) at the sides of the ETEP to ensure
adequate air intake and exhaust. If installing in an enclosed rack, make sure the rack has adequate
ventilation or an exhaust fan. An enclosed rack with a ventilation system that is too powerful can
prevent proper cooling by creating negative air pressure around the ETEP.
Mechanical Loading
Keep the center of gravity in the rack as low as possible. This ensures that the weight of the ETEP
will not make the rack unstable. Make sure that the rack is secured and use the proper mounting
hardware to secure the ETEP to the rack.
Circuit Loading
Consider the connection of the ETEP to the supply circuit and the effect that overloading of circuits
might have on overcurrent protection and supply wiring. Consult the voltage and amperage ratings on
the UL label affixed to the unit’s rear panel when addressing this concern.
Table 12 Third party management station software
Software How it’s used Vendor
FTP server Copies files to and from Black
Box appliances, including log
files and new firmware
Microsoft FTP server, included
with Windows XP
SFTP server (optional: available
with ETEP 1.6 and later)
Secures file transfers to and
from Black Box appliances
Cerberus FTP Server 4 –
Professional Edition
PDF reader Opens the user documentation
files on the product CD
Adobe Acrobat Reader version
6.0 or higher. Free download
available from www.adobe.com.
SSH client (ETEPs) Securely connects to the ETEP
CLI
PuTTY, included with the
EncrypTight Manager
installation