/X: or /x:—Use this option to exclude particular SCSI drives from having their
I/O handled by INIDISK.SYS. Excluded SCSI drives are identified by specifying the
host adapter, target ID, and LUN (logical unit number). These values are
separated by a colon. Groups of SCSI drives can also be identified. Examples of the
different ways CD-ROM drives can be excluded:
/X0:1:2 This will exclude the drive on SCSI Host Adapter 0 (that is, the
Adapter on the PCI bus that the motherboard has designated
number zero) whose target ID is 1 and whose LUN is 2.
/X0:2 This will exclude the drives on SCSI Host Adapter 0 whose target
ID is 2, no matter what LUN they have.
/X0 This will exclude all of the drives on SCSI Host Adapter 0.
When DOSSETUP installs INIDISK.SYS, it will add command lines like those
shown below to your CONFIG.SYS file. (These examples assume that the Adapter
drivers have been installed in the “C:\INIASPI” directory.)
CONFIG.SYS:
DEVICEHIGH=C:\INIASPI\ASPIA100.SYS
DEVICEHIGH=C:INIASPI\INIDISK.SYS /R2
The first line loads the ASPI Manager and the second line loads the SCSI disk driver,
specifying that a minimum of two drive letters be reserved for each MO and removable