SmartCell 6A000 User Guide 2-3
Switch Installation and Setup Installing the Switch
If the hardware configuration is incorrect, contact Cabletron customer support immediately.
2.2.1 DS3 and E3 I/O Module Configuration
Table 2-2 shows the pre-configured values for both the DS3 (6A-IOM-67-4) and E3 (6A-IOM-77-4) I/O modules.
These values cannot be changed. Accordingly, configure the connecting device’s interface to use these values.
2.3 INSTALLING THE SWITCH
The SmartCell 6A000 is hot swappable, meaning that you can install and remove it without turning off or unplugging
the SmartSwitch 6000 chassis. You can install as many as five switch modules in each chassis (using the 6C205-3
power supply). In this configuration, the SmartCell 6A000 modules provide up to 75 user ports. Modules should be
connected with inter-module trunks if traffic must cross between modules. Table 2-3 shows the maximum number of
LAN and ATM switch modules that can be installed in a SmartSwitch 6000 chassis.
6A-IOM-29-4-LR
155 Mbps OC-3/STS-1, SMF-LR/SC (4 port)
6A-IOM-31-1
622 Mbps OC-12/STM-4, MMF/SC (1 port)
6A-IOM-39-1
622 Mbps OC-12/STM-4, SMF-IR/SC (1 port)
6A-IOM-39-1-LR
622 Mbps OC-12/STM-4, SMF-LR/SC (1 port)
6A-IOM-67-4
45 Mbps DS-3, Coax/BNC (4 port)
6A-IOM-77-4
34 Mbps E-3, Coax/BNC (4 port)
Table 2-2 DS3 and E3 Module settings
Protocol Mode Framing Empty Cell Timing Scrambling Length
DS3
plcp cbit unassigned internal off greater than 225 ft.
E3
plcp G.751 unassigned internal off N/A
Table 2-3 SmartSwitch 6000 contents
Number of 6Exxx or 6Hxxx modules installed012345
Number of 6A000 modules that can be added543210
Table 2-1 I/O module ID numbers (Continued)
Face Plate Number Physical Specification